Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Int J Nanomedicine ; 19: 2137-2148, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476277

RESUMO

Purpose: Magnetic particle imaging (MPI) is an emerging medical imaging modality that is on the verge of clinical use. In recent years, cardiovascular applications have shown huge potential like, e.g., intraprocedural imaging guidance of stent placement through MPI. Due to the lack of signal generation, nano-modifications have been necessary to visualize commercial medical instruments until now. In this work, it is investigated if commercial interventional devices can be tracked with MPI without any nano-modification. Material and Methods: Potential MPI signal generation of nine endovascular metal stents was tested in a commercial MPI scanner. Two of the stents revealed sufficient MPI signal. Because one of the two stents showed relevant heating, the imaging experiments were carried out with a single stent model (Boston Scientific/Wallstent-Uni Endoprothesis, diameter: 16 mm, length: 60 mm). The nitinol stent and its delivery system were investigated in seven different scenarios. Therefore, the samples were placed at 49 defined spatial positions by a robot in a meandering pattern during MPI scans. Image reconstruction was performed, and the mean absolute errors (MAE) between the signals' centers of mass (COM) and ground truth positions were calculated. The stent material was investigated by magnetic particle spectroscopy (MPS) and vibrating sample magnetometry (VSM). To detect metallic components within the delivery system, nondestructive testing via computed tomography was performed. Results: The tracking of the stent and its delivery system was possible without any nano-modification. The MAE of the COM were 1.49 mm for the stent mounted on the delivery system, 3.70 mm for the expanded stent and 1.46 mm for the delivery system without the stent. The results of the MPS and VSM measurements indicate that besides material properties eddy currents seem to be responsible for signal generation. Conclusion: It is possible to image medical instruments with dedicated designs without modifications by means of MPI. This enables a variety of applications without compromising the mechanical and biocompatible properties of the instruments.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Magnetismo , Fenômenos Magnéticos
2.
J Hepatol ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38307346

RESUMO

Hepatocellular carcinoma (HCC) is the fourth leading cause of cancer death worldwide and its prognosis is highly heterogeneous, being related not only to tumour burden but also to the severity of underlying chronic liver disease. Moreover, advances in systemic therapies for HCC have increased the complexity of patient management. Randomised-controlled trials represent the gold standard for evidence generation across all areas of medicine and especially in the oncology field, as they allow for unbiased estimates of treatment effect without confounders. Observational studies have many problems that could reduce their internal and external validity. However, large prospective (well-conducted) observational real-world studies can detect rare adverse events or monitor the occurrence of long-term adverse events. How best to harness real world data, which refers to data generated from the routine care of patients, and real-world 'evidence', which is the evidence generated from real-world data, represents an open challenge. In this review article, we aim to provide an overview of the benefits and limitations of different study designs, particularly focusing on randomised-controlled trials and observational studies, to address important and not fully resolved questions in HCC research.

3.
Radiology ; 310(2): e231956, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38376407

RESUMO

Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária
4.
Radiology ; 310(2): e232044, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38319166

RESUMO

Background CT-guided high-dose-rate (HDR) brachytherapy (hereafter, HDR brachytherapy) has been shown to be safe and effective for patients with unresectable hepatocellular carcinoma (HCC), but studies comparing this therapy with other local-regional therapies are scarce. Purpose To compare patient outcomes of HDR brachytherapy and transarterial chemoembolization (TACE) in patients with unresectable HCC. Materials and Methods This multi-institutional retrospective study included consecutive treatment-naive adult patients with unresectable HCC who underwent either HDR brachytherapy or TACE between January 2010 and December 2022. Overall survival (OS) and progression-free survival (PFS) were compared between patients matched for clinical and tumor characteristics by propensity score matching. Not all patients who underwent TACE had PFS available; thus, a different set of patients was used for PFS and OS analysis for this treatment. Hazard ratios (HRs) were calculated from Kaplan-Meier survival curves. Results After propensity matching, 150 patients who underwent HDR brachytherapy (median age, 71 years [IQR, 63-77 years]; 117 males) and 150 patients who underwent TACE (OS analysis median age, 70 years [IQR, 63-77 years]; 119 male; PFS analysis median age, 68 years [IQR: 63-76 years]; 119 male) were analyzed. Hazard of death was higher in the TACE versus HDR brachytherapy group (HR, 4.04; P < .001). Median estimated PFS was 32.8 months (95% CI: 12.5, 58.7) in the HDR brachytherapy group and 11.6 months (95% CI: 4.9, 22.7) in the TACE group. Hazard of disease progression was higher in the TACE versus HDR brachytherapy group (HR, 2.23; P < .001). Conclusion In selected treatment-naive patients with unresectable HCC, treatment with CT-guided HDR brachytherapy led to improved OS and PFS compared with TACE. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Chapiro in this issue.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Adulto , Idoso , Humanos , Masculino , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
5.
AJR Am J Roentgenol ; 222(3): e2330481, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197760

RESUMO

BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.


Assuntos
Estenose Coronária , Placa Aterosclerótica , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Constrição Patológica , Tomografia Computadorizada por Raios X/métodos , Estenose Coronária/diagnóstico por imagem
6.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982533

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração , Função Ventricular Esquerda
7.
Front Med (Lausanne) ; 10: 1272893, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38076269

RESUMO

Introduction: The best way to impart knowledge to medical students is still unclear. Therefore, we designed a blended learning course in thoracic radiology including both "traditional" in-class time as well as online learning modules. The aims were (1) to investigate students' attitudes toward this blended learning approach; and (2) to test whether it improved their knowledge about thoracic radiology. Methods: A prospective study was conducted at the local medical center; 156 fourth-year medical students completed this study. Before and after the course, students had to complete (1) questionnaires to investigate their attitudes (7-point Likert scale); and (2) an objective test to assess their knowledge (multiple-choice/free text questions; results as % of correct answers). Results: Regarding (1), the course led to an improvement in all items compared to baseline, exemplary: interest in thoracic radiology (precourse 4.2 vs. 5.4 postcourse) and the fulfillment of students' expressed requirements regarding the teaching content (4.5 precourse vs. 6.2 postcourse). Furthermore, the great majority (88%) of our participants wished for more online learning offerings in the future. Regarding (2), the course led to improved knowledge on the objective test (precourse: 40% vs. postcourse: 63% correct answers). Conclusion: This feasibility study showed the successful design and implementation of a blended learning approach in thoracic radiology. Furthermore, it revealed medical students' positive attitudes toward this approach and showed an increased knowledge in thoracic radiology. Thus, such approaches might be used to enrich the teaching armamentarium in medical education and to further enhance interest and knowledge in thoracic diseases among medical students.

8.
Sci Rep ; 13(1): 22178, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38092810

RESUMO

Percutaneous drainage is a first-line therapy for abscesses and other fluid collections. However, experimental data on the viscosity of body fluids are scarce. This study analyses the apparent viscosity of serous, purulent and biliary fluids to provide reference data for the evaluation of drainage catheters. Serous, purulent and biliary fluid samples were collected during routine drainage procedures. In a first setup, the apparent kinematic viscosity of 50 fluid samples was measured using an Ubbelohde viscometer. In a second setup, the apparent dynamic viscosity of 20 fluid samples obtained during CT-guided percutaneous drainage was measured using an in-house designed capillary extrusion experiment. The median apparent kinematic viscosity was 0.96 mm2/s (IQR 0.90-1.15 mm2/s) for serous samples, 0.98 mm2/s (IQR 0.97-0.99 mm2/s) for purulent samples and 2.77 mm2/s (IQR 1.75-3.70 mm2/s) for biliary samples. The median apparent dynamic viscosity was 1.63 mPa*s (IQR 1.27-2.09 mPa*s) for serous samples, 2.45 mPa*s (IQR 1.69-3.22 mPa*s) for purulent samples and 3.50 mPa*s (IQR 2.81-3.90 mPa*s) for biliary samples (all differences p < 0.01). Relative to water, dynamic viscosities were increased by a factor of 1.36 for serous fluids, 2.26 for purulent fluids, and 4.03 for biliary fluids. Serous fluids have apparent viscosities similar to water, but biliary and purulent fluids are more viscous. These data can be used as a reference when selecting the drainage catheter size, with 8F catheters being appropriate for most percutaneous drainage cases.


Assuntos
Abscesso , Drenagem , Humanos , Viscosidade , Drenagem/métodos , Abscesso/terapia , Cateteres , Água
9.
Diagnostics (Basel) ; 13(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38066763

RESUMO

Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.

10.
Diagnostics (Basel) ; 13(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38132206

RESUMO

BACKGROUND: Handheld ultrasound (HHUS) devices have chiefly been deployed in emergency medicine, where they are considered a valid tool. The data situation is less clear in the case of internal questions in abdominal sonography. In our study, we investigate whether HHUS devices from different manufacturers differ in their B-scan quality, and whether any differences are relevant for the significance of an internal ultrasound examination. METHOD: The study incorporated eight HHUS devices from different manufacturers. Ultrasound videos of seven defined sonographic questions were recorded with all of the devices. The analogue recording of the same findings with a conventional high-end ultrasound (HEUS) device served as an evaluation criterion. Then, the corresponding findings were played side by side and evaluated by fourteen ultrasound experts using a point scale (5 points = very good; 1 point = insufficient). RESULTS: The HHUS devices achieved relatively good results in terms of both the B-scan quality assessment and the ability to answer the clinical question, regardless of the manufacturer. One of the tested HHUS devices even achieved a significantly (p < 0.05) higher average points score in both the evaluation of B-scan quality and in the evaluation of clinical significance than the other devices. Regardless of the manufacturer, the HHUS devices performed best when determining the status/inferior vena cava volume and in the representation of ascites/free fluid. CONCLUSION: In various clinical abdominal sonography questions, HHUS systems can reliably reproduce findings, and are-while bearing their limitations in mind-an acceptable alternative to conventional HEUS systems. Irrespective of this, the present study demonstrated relevant differences in the B-scan quality of HHUS devices from different manufacturers.

11.
Acad Radiol ; 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38155024

RESUMO

RATIONALE AND OBJECTIVES: The prognostic role of pericardial effusion (PE) in Covid 19 is unclear. The aim of the present study was to estimate the prognostic role of PE in patients with Covid 19 in a large multicentre setting. MATERIALS AND METHODS: This retrospective study is a part of the German multicenter project RACOON (Radiological Cooperative Network of the Covid 19 pandemic). The acquired sample comprises 1197 patients, 363 (30.3%) women and 834 (69.7%) men. In every case, chest computed tomography was analyzed for PE. Data about 30-day mortality, need for mechanical ventilation and need for intensive care unit (ICU) admission were collected. Data were evaluated by means of descriptive statistics. Group differences were calculated with Mann-Whitney test and Fisher exact test. Uni-and multivariable regression analyses were performed. RESULTS: Overall, 46.4% of the patients were admitted to ICU, mechanical lung ventilation was performed in 26.6% and 30-day mortality was 24%. PE was identified in 159 patients (13.3%). The presence of PE was associated with 30-day mortality: HR= 1.54, CI 95% (1.05; 2.23), p = 0.02 (univariable analysis), and HR= 1.60, CI 95% (1.03; 2.48), p = 0.03 (multivariable analysis). Furthermore, density of PE was associated with the need for intubation (OR=1.02, CI 95% (1.003; 1.05), p = 0.03) and the need for ICU admission (OR=1.03, CI 95% (1.005; 1.05), p = 0.01) in univariable regression analysis. The presence of PE was associated with 30-day mortality in male patients, HR= 1.56, CI 95%(1.01-2.43), p = 0.04 (multivariable analysis). In female patients, none of PE values predicted clinical outcomes. CONCLUSION: The prevalence of PE in Covid 19 is 13.3%. PE is an independent predictor of 30-day mortality in male patients with Covid 19. In female patients, PE plays no predictive role.

12.
J Vasc Surg Cases Innov Tech ; 9(4): 101337, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37965116

RESUMO

Port implantation can be associated with an array of serious vascular complications, typically involving the subclavian artery. We report a case in which implantation of a port resulted in iatrogenic perforation of the aortic arch at the level of the left subclavian artery, which was sealed off using a percutaneous vascular closure device.

13.
Diagnostics (Basel) ; 13(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37892093

RESUMO

BACKGROUND: ultrasound diagnostics have a broad spectrum of applications, including among diseases of the musculoskeletal system. Accordingly, it is important for the users to have a well-founded and up-to-date education in this dynamic examination method. The right balance between online and in-class teaching still needs to be explored in this context. Certifying institutions are currently testing digitally transformed teaching concepts to provide more evidence. METHODS: this study compared two musculoskeletal ultrasound blended learning models. Model A was more traditional, with a focus on in-person teaching, while Model B was more digitally oriented with compulsory webinar. Both used e-learning for preparation. Participants completed evaluations using a seven-point Likert scale, later converted to a 0-1 scale. Digital teaching media (e-learning) were used for preparation in both courses. RESULTS: the analysis included n = 41 evaluations for Model A and n = 30 for Model B. Model B received a better overall assessment (median: 0.73 vs. 0.69, p = 0.05). Model B also excelled in "course preparation" (p = 0.02), "webinar quality" (p = 0.04), and "course concept" (p = 0.04). The "gain of competence" (p = 0.82), "learning materials" (p = 0.30), and "tutor quality" (p = 0.28) showed no significant differences. CONCLUSION: participants favorably assessed blended learning in ultrasound teaching. Certifying institutions should consider accrediting models that combine digital methods (e.g., internet lectures/webinars) and materials (e.g., e-learning) with hands-on ultrasound training. Further research is needed to validate these subjective findings for a stronger evidential basis.

14.
BMC Med Educ ; 23(1): 723, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37789302

RESUMO

BACKGROUND: Point-of-care Ocular Ultrasound (POCOUS) has gained importance in emergency medicine and intensive care in recent years. This work aimed to establish and evaluate a dedicated ultrasound education program for learning POCOUS-specific skills during medical studies at a university hospital. METHODS: The blended learning-based program (6 teaching units) based on recent scientific publications and recommendations was developed for students in the clinical part of their medical studies. Experts and trainers consisted of physicians from the Ear-Nose-Throat, radiology, ophthalmology and neurology specialties as well as university educational specialists. Lecture notes containing digital video links for preparation was produced as teaching material. In total, 33 students participated in the study. The education program, including the teaching materials, motivation and subjective gain in competency, was evaluated with the aid of a questionnaire (7-point Likert response format). Objective learning success was assessed on the basis of pre- and post-tests. These covered the skill areas: "anatomical basics", "ultrasound basics", "understanding of cross-sectional images", "normal findings" and "pathology recognition". RESULTS: In the objective assessment of image interpretation, the participants improved significantly (p < 0.001) from pre- to post-test with a large effect size (Cohen's d = 1.78, effect size r = 0.66). The evaluations revealed a high level of satisfaction with the course concept, teaching materials and the tutors. In addition, a high level of motivation was recorded in relation to continuing to study "ultrasound diagnostics" and "ophthalmologic diseases". A significant (p < 0.01) positive gain was also achieved in terms of the subjective assessment of competency. This covers areas such as expertise, sonographic anatomy and performing a POCOUS examination as well as recognizing retinal detachment, globe perforation and increased optic nerve sheath diameter. CONCLUSION: The results of this feasibility study show that medical students accept and support a POCOUS-specific education program and are able to develop a higher objective and subjective level of competency. Future transfer to other sites and larger groups of participants seems feasible.


Assuntos
Estudantes de Medicina , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Currículo , Ultrassonografia , Aprendizagem , Competência Clínica
15.
Hepatol Commun ; 7(10)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756031

RESUMO

BACKGROUND: Postembolization syndrome (PES) represents the most frequent complication after transarterial chemoembolization (TACE) in patients with HCC. Given the vague definition as a symptom complex comprising abdominal pain, fever, and nausea, PES is diagnosed in heterogeneous patient cohorts with symptoms ranging from mild pain to severe deterioration of their general condition. This study aimed to evaluate predictive factors and the prognostic impact of PES with regard to different severity grades. METHODS: A total of 954 patients treated with TACE for HCC at the University Medical Centres Mainz and Freiburg were included in this study. PES disease severity was graded as mild, moderate, or severe according to a predefined combination of symptoms. Logistic regression models were used to identify independent predictors of PES. The prognostic impact of PES was evaluated by competing risk analyses considering liver transplantation as a competing risk. RESULTS: PES occurred in 616 patients (64.5%), but only 56 patients (5.9%) had severe PES, defined as moderate to severe abdominal pain requiring opioids in combination with fever and nausea. The largest tumor diameter was the strongest independent predictor of PES (OR = 1.21, 95% CI = 1.13-1.28), and severe PES (OR = 1.23, 95% CI = 1.14-1.33, p < 0.0001). Presence of liver cirrhosis was protective against PES (OR = 0.48, 95% CI = 0.27-0.84, p = 0.01). Furthermore, PES was independently associated with an impaired disease control rate (OR = 0.33, 95% CI = 0.16-0.69, p = 0.003) and severe PES with poor overall survival (subdistribution HR = 1.53, 95% CI = 0.99-2.36, p = 0.04). CONCLUSIONS: Tumor size and absence of liver cirrhosis are predictors of severe PES and associated with impaired prognosis in HCC patients after TACE.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Quimioembolização Terapêutica/efeitos adversos , Prognóstico , Náusea/etiologia , Náusea/terapia , Dor Abdominal/etiologia , Dor Abdominal/terapia , Cirrose Hepática/etiologia
16.
Insights Imaging ; 14(1): 150, 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37726485

RESUMO

BACKGROUND: Written medical examinations consist of multiple-choice questions and/or free-text answers. The latter require manual evaluation and rating, which is time-consuming and potentially error-prone. We tested whether natural language processing (NLP) can be used to automatically analyze free-text answers to support the review process. METHODS: The European Board of Radiology of the European Society of Radiology provided representative datasets comprising sample questions, answer keys, participant answers, and reviewer markings from European Diploma in Radiology examinations. Three free-text questions with the highest number of corresponding answers were selected: Questions 1 and 2 were "unstructured" and required a typical free-text answer whereas question 3 was "structured" and offered a selection of predefined wordings/phrases for participants to use in their free-text answer. The NLP engine was designed using word lists, rule-based synonyms, and decision tree learning based on the answer keys and its performance tested against the gold standard of reviewer markings. RESULTS: After implementing the NLP approach in Python, F1 scores were calculated as a measure of NLP performance: 0.26 (unstructured question 1, n = 96), 0.33 (unstructured question 2, n = 327), and 0.5 (more structured question, n = 111). The respective precision/recall values were 0.26/0.27, 0.4/0.32, and 0.62/0.55. CONCLUSION: This study showed the successful design of an NLP-based approach for automatic evaluation of free-text answers in the EDiR examination. Thus, as a future field of application, NLP could work as a decision-support system for reviewers and support the design of examinations being adjusted to the requirements of an automated, NLP-based review process. CLINICAL RELEVANCE STATEMENT: Natural language processing can be successfully used to automatically evaluate free-text answers, performing better with more structured question-answer formats. Furthermore, this study provides a baseline for further work applying, e.g., more elaborated NLP approaches/large language models. KEY POINTS: • Free-text answers require manual evaluation, which is time-consuming and potentially error-prone. • We developed a simple NLP-based approach - requiring only minimal effort/modeling - to automatically analyze and mark free-text answers. • Our NLP engine has the potential to support the manual evaluation process. • NLP performance is better on a more structured question-answer format.

17.
Cancer Imaging ; 23(1): 69, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37480062

RESUMO

BACKGROUND: Excellent image quality is crucial for workup of hepatocellular carcinoma (HCC) in patients with liver cirrhosis because a signature tumor signal allows for non-invasive diagnosis without histologic proof. Photon-counting detector computed tomography (PCD-CT) can enhance abdominal image quality, especially in combination with a novel iterative reconstruction algorithm, quantum iterative reconstruction (QIR). The purpose of this study was to analyze the impact of different QIR levels on PCD-CT imaging of HCC in both phantom and patient scans. METHODS: Virtual monoenergetic images at 50 keV were reconstructed using filtered back projection and all available QIR levels (QIR 1-4). Objective image quality properties were investigated in phantom experiments. The study also included 44 patients with triple-phase liver PCD-CT scans of viable HCC lesions. Quantitative image analysis involved assessing the noise, contrast, and contrast-to-noise ratio of the lesions. Qualitative image analysis was performed by three raters evaluating noise, artifacts, lesion conspicuity, and overall image quality using a 5-point Likert scale. RESULTS: Noise power spectra in the phantom experiments showed increasing noise suppression with higher QIR levels without affecting the modulation transfer function. This pattern was confirmed in the in vivo scans, in which the lowest noise levels were found in QIR-4 reconstructions, with around a 50% reduction in median noise level compared with the filtered back projection images. As contrast does not change with QIR, QIR-4 also yielded the highest contrast-to-noise ratios. With increasing QIR levels, rater scores were significantly better for all qualitative image criteria (all p < .05). CONCLUSIONS: Without compromising image sharpness, the best image quality of iodine contrast optimized low-keV virtual monoenergetic images can be achieved using the highest QIR level to suppress noise. Using these settings as standard reconstruction for HCC in PCD-CT imaging might improve diagnostic accuracy and confidence.


Assuntos
Carcinoma Hepatocelular , Iodo , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Algoritmos
18.
Tomography ; 9(4): 1315-1328, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37489472

RESUMO

INTRODUCTION: Ultrasound diagnostics is an important examination method in everyday clinical practice, but student education is often inadequate for acquiring sufficient basic skills. Individual universities have therefore started integrating (extra)curricular training concepts into medical education. This study aimed to evaluate sustainable skills development through participation in peer-assisted ultrasound courses. METHODS: From 2017, students in the clinical part of medical school could opt for extracurricular peer-assisted ultrasound courses. Depending on the format (10-week course/2-day compact course) these comprised 20 teaching units focusing on abdominal and emergency ultrasonography. Students attending compulsory workshops at the start of their practical year were enrolled in this study, allowing for a comparison between the study group (attended ultrasound course) and the control group (did not attend ultrasound course). Competency from two out of four practical exams (subjects: "aorta", "gallbladder", "kidney" and "lung") was measured, and a theory test on the same subject areas ("pathology recognition") was administered. Additional questions concerned biographical data, subjective competency assessment (7-point Likert scale), and "attitude to ultrasound training in the curriculum". RESULTS: Analysis included 302 participants in total. Ultrasound courses had been attended on average 2.5 years earlier (10-week course) and 12 months earlier (2-day compact course), respectively. The study group (n = 141) achieved significantly better results than the control group (n = 161) in the long-term follow-up. This applies both to practical exams (p < 0.01) and theory tests (p < 0.01). After course attendance, participants reported a significantly higher subjective assessment of theoretical (p < 0.01) and practical (p < 0.01) ultrasound skills. CONCLUSIONS: Peer-assisted ultrasound courses can sustainably increase both theoretical and practical competency of medical students. This highlights the potential and need for standardised implementation of ultrasound courses in the medical education curriculum.


Assuntos
Rim , Faculdades de Medicina , Humanos , Estudos Prospectivos , Ultrassonografia
19.
Eur J Radiol ; 165: 110892, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37269571

RESUMO

PURPOSE: The purpose of this study was to assess the efficacy of transarterial embolization in COVID-19 patients with an arterial bleeding and to investigate differences between various patient groups concerning survival. METHOD: We retrospectively reviewed COVID-19 patients undergoing transarterial embolization due to an arterial bleeding in a multicenter study from April 2020 to July 2022 and analyzed the technical success of embolization and survival rate. 30-day survival between various patient groups was analyzed. The Chi- square test and Fisher's exact test were used for testing association between the categorical variables. RESULTS: 53 COVID-19 patients (age: 57.3 ± 14.3 years, 37 male) received 66 angiographies due to an arterial bleeding. The initial embolization was technically successful in 98.1% (52/53). In 20.8% (11/53) of patients, additional embolization was necessary due to a new arterial bleeding. A majority of 58.5% (31/53) had a severe course of COVID-19 infection necessitating ECMO-therapy and 86.8% (46/53) of patients received anticoagulation. 30-day survival rate in patients with ECMO-therapy was significantly lower than without ECMO-therapy (45.2% vs. 86.4%, p = 0.004). Patients with anticoagulation did not have a lower 30-day survival rate than without anticoagulation (58.7% vs. 85.7%, p = 0.23). COVID-19 patients with ECMO-therapy developed more frequently a re-bleeding after embolization than non-ECMO-patients (32.3% vs. 4.5%, p = 0.02). CONCLUSIONS: Transarterial embolization is a feasible, safe, and effective procedure in COVID-19 patients with arterial bleeding. ECMO-patients have a lower 30-day survival rate than non-ECMO-patients and have an increased risk for re-bleeding. Treatment with anticoagulation could not be identified as a risk factor for higher mortality.


Assuntos
COVID-19 , Embolização Terapêutica , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Anticoagulantes/uso terapêutico , COVID-19/complicações , COVID-19/terapia , Embolização Terapêutica/métodos , Hemorragia/diagnóstico por imagem , Hemorragia/terapia , Hemorragia/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Feminino
20.
J Cardiovasc Magn Reson ; 25(1): 33, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37331991

RESUMO

BACKGROUND: MRI T2 mapping has been proven to be sensitive to the level of blood oxygenation. We hypothesized that impaired exercise capacity in chronic heart failure is associated with a greater difference between right (RV) to left ventricular (LV) blood pool T2 relaxation times due to a higher level of peripheral blood desaturation, compared to patients with preserved exercise capacity and to healthy controls. METHODS: Patients with chronic heart failure (n = 70) who had undergone both cardiac MRI (CMR) and a 6-min walk test (6MWT) were retrospectively identified. Propensity score matched healthy individuals (n = 35) served as control group. CMR analyses included cine acquisitions and T2 mapping to obtain blood pool T2 relaxation times of the RV and LV. Following common practice, age- and gender-adjusted nominal distances and respective percentiles were calculated for the 6MWT. The relationship between the RV/LV T2 blood pool ratio and the results from 6MWT were evaluated by Spearman's correlation coefficients and regression analyses. Inter-group differences were assessed by independent t-tests and univariate analysis of variance. RESULTS: The RV/LV T2 ratio moderately correlated with the percentiles of nominal distances in the 6MWT (r = 0.66) while ejection fraction, end-diastolic and end-systolic volumes showed no correlation (r = 0.09, 0.07 and - 0.01, respectively). In addition, there were significant differences in the RV/LV T2 ratio between patients with and without significant post-exercise dyspnea (p = 0.001). Regression analyses showed that RV/LV T2 ratio was an independent predictor of the distance walked and the presence of post-exercise dyspnea (p < 0.001). CONCLUSION: The proposed RV/LV T2 ratio, obtained by two simple measurements on a routinely acquired four-chamber T2 map, was superior to established parameters of cardiac function to predict exercise capacity and the presence of post-exercise dyspnea in patients with chronic heart failure.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Estudos Retrospectivos , Tolerância ao Exercício , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...